Influenza A/B+COVID-19/RSV Combo Ag Test (For Self-Testing)
Influenza A/B+COVID-19/RSV Combo Ag Test (For Self-Testing)
Influenza A/B+COVID-19/RSV Combo Ag Test is an in vitro immunochromatographic assay for the qualitative and differential detection of nucleocapsid protein antigen from influenza A (including the subtype H1N1), influenza B,respiratory syncytial virus and/or SARS-CoV-2 in nasal swab specimens. It is intended to aid in the rapid diagnosis of influenza A, influenza B, respiratory syncytial virus and/or SARS-CoV-2 infections.This test is intended for non-prescription home users.
Contact us
Product Information
INTENDED USE:
Influenza A/B+COVID-19/RSV Combo Ag Test is an in vitro immunochromatographic assay for the qualitative and differential detection of nucleocapsid protein antigen from influenza A (including the subtype H1N1), influenza B,respiratory syncytial virus and/or SARS-CoV-2 in nasal swab specimens. It is intended to aid in the rapid diagnosis of influenza A, influenza B, respiratory syncytial virus and/or SARS-CoV-2 infections.This test is intended for non-prescription home use
rs.
ADVANTAGE:
*Non-invasive sampling
*Rapid Test (Test result available in 15 min.)
*Read test results visually.
*Do not require test equipment.
*Simple Operation.
TEST PROCEDURE:
1.Remove the test from the sealed pouch. Lay it on a flat, clean and dry surface.
2.Reverse the sample collection tube, and add 3 drops of test sample by squeezing the collection solution tube into each of the sample well.
3.Read results at 15 minutes.
INTERPRETATION OF RESULTS:

For Flu A/B Antigen Test 1.POSITIVE:
1.1 Flu A Positive:
The presence of two lines as control line (C) and T1 test line within the result window indicates a positive result for Influenza A viral antigen.
1.2 Flu B Positive:
The presence of two lines as control line (C) and T2 test line within the result window indicates a positive result for Influenza B viral antigen.
1.3 Flu A+B Positive:
The presence of three lines as control line (C), T1 test line and T2 test line within the result window indicates a positive result for Influenza A and Influenza B viral antigen.
2.NEGATIVE:
The presence of only control band (C) within the result window indicates a negative result.
3.INVALID:
If the control band (C) is not visible within the result window after performing the test, the result is considered invalid. Some causes of invalid results are because of not following the directions correctly or the test may have deteriorated beyond the expiration date. It is recommended that the specimen be re-tested using a new test. If the problem persists, please stop using the product and and contact with the test distributor.
 
For COVID-19/RSV Antigen Test
1.POSITIVE:
1.1 RSV Positive:
The presence of two lines as control line (C) and T1 test line within the result window indicates a positive result for RSV viral antigen.
1.2 COVID-19 Positive:
The presence of two lines as control line (C) and T2 test line within the result window indicates a positive result for COVID-19 viral antigen. If tested COVID-19 positive, users should not take any decision of medical relevance without first consulting a medical practitioner.
1.3 COVID-19+RSV Positive:
The presence of three lines as control line (C), T1 test line and T2 test line within the result window indicates a positive result for RSV and COVID-19 viral antigen.
2.NEGATIVE:
The presence of only control band (C) within the result window indicates a negative result.
3.INVALID:
If the control band (C) is not visible within the result window after performing the test, the result is considered invalid. Some causes of invalid results are because of not following the directions correctly or the test may have deteriorated beyond the expiration date. It is recommended that the specimen be re-tested using a new test. If the problem persists, please stop using the product and contact with the test distributor.
SPECIFICATION:  
Description Specimen Format Catalog No. Sensitivity Package Size Strip Width Certificate
Influenza A/B+COVID-19/RSV Combo Ag Test
(For Self-Testing)
Nasal Swab Multi-Panel BP292-01 INF A:100%
 INF B: 96%
COVID-19 AG:
cts≤25,98.67%
cts≤30,93%
cts≥30,89.09%
RSV:98.98%
1 Test 4.0 mm CE2934
BP292-02   2 Tests 4.0 mm
BP292-04 1 Test   4.0 mm
BP292-05 5 Tests 4.0 mm
BP292-25 25 Tests 4.0 mm
 
 
 
 